Three to four
diameters of settling distance between the VSR and the flow meter
installation location are required to allow the turbulence
intensity to decrease while maintaining the repeatable velocity
profile. This provides an optimal flow scenario for flow
meters of all technologies installing the VSR flow conditioner can
be accommodated by a variety of process connections including
flanged, threaded, grooved, weld prepped, or customer specified.
VORTAB flow conditioners provide the lowest
pressure loss solutions to flow profile irregularities caused by
elbows, valves, blowers, compressors and other disruptions that
commonly occur in piping and duct runs.
|
Applications |
|
u
Piping with inadequate straight runs |
|
u Flow
conditioning for calibration and/or test benches and flow
meters |
|
u
Temperature and pressure stratification |
|
u
Processes that require repeatable, symmetric and swirl-free
velocity flow profiles |
|
u
Process conditioning for control valves, blowers, compressors,
burners and other
critical process equipment |
Specifications
Process
Media:
u Gases,
liquids, slurries, and particulate mixes such as pulverized coal
and air
Materials and sizes:
u 316L
stainless steel: 2" and larger.
u Carbon
steel: 8” and larger.
u
Hastelloy
C: 2” and larger.
u Other
materials and sizes are available
Pipe Schedule:
u All pipe
schedules available
u
Schedule10, 40, and 80 are standard options
Standard Process connections:
u Weld
preparation
u Flanged,
up to 600 lb rating *(heavier class flanges available)
u
Male NPT,
up to 4 inch pipe size
u
Additional
process connections available, consult factory
Flow
Conditioner Length:
u3
pipe diameters
For any
other required options or special features not listed above,
please contact VORTAB. |